KEYWORD SEARCH

Vacuum Regulation.

Push-To-Set™ 2-Mode Continuous Regulator.

Ohio Medical Push-To-Set™ Continuous Vacuum Regulator with Standard, Low or High gauge for use with all common suction therapy procedures. Regulator shall provide continuous, regulated suction from a piped vacuum system. Gauge is calibrated in mmHg with glow-in-the-dark increments and needle and is protected with a snapfit lens. Suction Control Knob is large and unobstructed. Mode Selector Switch has a toggle action for easy, positive selection which shows the selected mode from a distance. Components are modular for ease of replacement. Vacuum regulator is compact, lightweight and made of strong, break-resistant plastic. It shall be equipped with specified adapter, fitting and accessories. Regulator Module and Gauge are interchangeable with Ohio Medical Intermittent Suction Unit (ISU).

Features

  • Available with Analogue or Digital displays for ease of use
  • Built-in Patented Push-To-Set™ feature
  • Top mounted on/off switch for ease of use
  • Brighter glow-in-the-dark gauge increments and needle
  • Smaller, sleek design for tight spaces
  • Baby icon indicates Pediatric/Neonatal

Standard Model Specifications

Flow Rate: 0-80 Lpm without fittings at full increase
Gauge Accuracy: ± 5% Full Scale Deflection
Dimensions: 5.7”H x 3.0”W x 4.8”D (17.8 x 7.62 x 10.16 cm)
Weight: 11 oz (0.289 Kg)
Warranty: Ten Years
F.O.B. Point: Gurnee, IL USA
Standards: Confirms to ISO 10079-3 and ASTM F960
Vacuum Range: 0 - Full Vacuum

Paediatric Model Specifications

Gauge: Low Vacuum 0-21 kPa/0-160 mmHg
Flow Rate: 0-80 Lpm without fittings at full increase
Gauge Accuracy: ± 5% Full Scale Deflection or ± 1.3 kPa (10 mmHg)
Dimensions: 17.8 x 7.62 x 10.16 cm (5.7”H x 3.0”W x 4.8”D)
Weight: 0.289 Kg. (11 oz)
Modes: I (ON), O (OFF)
Color Band: Low(green), Medium(yellow), High(orange)
Regulated Vacuum: 0-18.0 kPa/0-135 mmHg
Standards: Conforms to ISO 10079-3 and ASTM F960
Safety Device: Backup Safety Relief Valve
Peak Vacuum Available: 11-20 kPa (80-150 mmHg)

The Pediatric low-vacuum model includes a negative pressure limit to restrict maximum negative pressure or vacuum to 19 kPa (140 mmHg).

Neonatal Model Specifications

Flow Rate: 0-80 Lpm without fittings at full increase
Gauge Accuracy: ± 5% Full Scale Deflection or ± 1.3 kPa (10 mmHg)
Dimensions: 17.8 x 7.62 x 10.16 cm (5.7”H x 3.0”W x 4.8”D)
Weight: 0.289 Kg. (11 oz)
Modes: I (ON), O (OFF)
Color Band: Low(green), Medium(yellow), High(orange)
Regulated Vacuum: 0-13.3 kPa/0-100 mmHg
Standards: Conforms to ISO 10079-3 and ASTM F960
Safety Device: Backup Safety Relief Valve

The Neonatal low-vacuum model includes a negative pressure limit to restrict maximum negative pressure or vacuum to 13.3 kPa (100 mmHg).